HA-FOJBF-OA-01SM-5
HYBRIFLEX® Optical Fiber Cabling Solution,1 Pair, Armored Bend-Insensitive Single-Mode Fiber with LC/FullAXS to ODC Connectors

FEATURES / BENEFITS

  • Armored, bend-insensitive fiber design with outstanding bending characteristics → Eases installation and provides long-term reliability
  • Lightweight solution and compact design → Decreases tower loading
  • Robust cabling → Eliminates need for expensive cable trays and ducts
  • Packaging includes a Pulling Connector → Protects the jumper assembly and speeds up the installation process
  • Indoor/Outdoor, black PVC jacket – Ensures long-lasting cable protection
  • 100% Factory tested - Online test results available


Technical features

Structure

Cable TypeHYBRIFLEX®
Fire PerformanceFlame Retardant
Lengthm (ft)5 (16.4)

Mechanical Specifications

Outer Diameter Nominal mm (in)4.8 (0.189)
Minimum Bending Radius, Single Bendmm (in)40 (1.57)
Recommended / Maximum Clamp Spacing m (ft)1 / 1.2 (3.25 / 4)

DC Power Cable Specifications

DC Wire Jacket MaterialFlame Retardant, indoor/outdoor, PVC, Black
DC Standards (Meets or Exceeds)RoHS Compliant

Cable Jacket

UV-Protection Individual and External JacketYes
Jacket MaterialFlame Retardant, indoor/outdoor, PVC, Black

Armor Specifications

Armor TypeStainless Steel

F/O Cable Specifications

F/O Cable TypeSingle Mode, Bend Tolerant
Number of F/O Pairs1
Core/Clad µm9 /125
Secondary Protection Nominal µm (in)900 (0.035)
F/O Standards (Meets or Exceeds)RoHS Compliant
Optical LossdB/Km0.5 @ 1310 nm
0.5 @ 1550 nm
Fiber Termination End 1LC Connector With FullAXS Compatibility
Fiber Termination End 2ODC Plug
Cable sealing methodSemi-rigid flame-retarded polyolefin, with hot melt adhesive

Testing and Environmental

Storage Temperature °C (°F)-40 to 80 (-40 to 176 )
Operation Temperature °C (°F)-40 to 80 (-40 to 176 )
Installation Temperature °C (°F)-20 to 65 (-4 to 149 )
Alarm Wire Standards (Meets or Exceeds)RoHS Compliant


External Document Links