Radio Frequency Systems company website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

RL318 Series
Undefined product name

RFS rigid line components are available for both unpressurized (indoor) and pressurized, flanged (outdoor) systems. ;
Sizes available are 7/8", 1-5/8", 3-1/8", 4-1/2", 4-7/8", 6-1/8" and 7-3/16�.
All components are manufactured to the most exacting tolerances.
Other line sizes are available on special order.

FEATURES / BENEFITS

� Line inner and outer tubing is of high conductivity, hard-drawn, copper, milled to exact dimensions. Unflanged components for indoor use are polished and sprayed with a clear lacquer to maintain a high lustre finish
� Flanges and mitred elbow joints are TIG welded for maximum strength
� Captive PTFE dielectric insulators are used exclusively in lines and elbows to ensure precision mating and stability of components after assembly
� All inner conductor connectors are silver plated
� All components conform to the relevant EIA or IEC standards

Technical features


Structure

Product LineComponents
Product TypeCopper Rigid Line Components 3-1/8" 50 ohm
Size3-1/8
Feeder TypeAir Dielectric, solid inner and outer PTFE spacers
Conductor MaterialHigh conductivity copper tube
Outer Conductor OD mm (in)79.4 (3.125)
Outer Conductor ID mm (in)76.8 (3.023)
Inner Conductor OD mm (in)33.4 (1.315)
Inner Conductor ID mm (in)31.3 (1.232)

Electrical Specifications

Frequency Range MHz50 - 862
ImpedanceΩ50 +/- 0.5
Relative Propagation Velocity%99,8
Peak Power Rating kW920
RF Peak VoltagekV9600

Mechanical Specifications

Weight kg/m (lb/ft)3.6 (2.41)
Flange Weight kg (lb)1 (2.2)
Flange StandardEIA
Standard lengths m (ft)5.5 (18)
Recommended clamp spacing m (ft)1.5 (5)
Max. exterior clamp spacing m (ft)1.2 (4)

External Document Links