Radio Frequency Systems company website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

HCA900-50T
9" HELIFLEX® Air-Dielectric Coaxial Cable

HELIFLEX® 9" low loss air dielectric cable; high power

FEATURES / BENEFITS

  • Low Attenuation
    The low attenuation of HELIFLEX® coaxial cable results in highly efficient signal transfer in your RF system.
  • Complete Shielding
    The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
    Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    HELIFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
       Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
    materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.


9" HELIFLEX® Air Dielectric Coaxial Cable

Technical features

Applications

ApplicationsTV & RadioHF DefenseCable Solutions

Structure

Cable TypeAir-Dielectric, Corrugated
Size9
Jacket OptionBlack
Inner Conductormm (in)99.4 (3.91)
Inner Conductor MaterialCorrugated Copper Tube
Dielectricmm (in)216.7 (8.53)
Dielectric MaterialDistinct Fluoropolymer Spacer
Outer Conductormm (in)247.7 (9.75)
Outer Conductor MaterialCorrugated Aluminium
Jacket MaterialN/A

Testing and Environmental

Fire PerformanceFlame Retardant, LS0H
Installation Temperature °C(°F)-40 to 60 (-40 to 140)
Storage Temperature°C(°F)-70 to 85 (-94 to 185)
Operation Temperature °C(°F)-50 to 85 (-58 to 185)

Electrical Specifications

Impedance, OhmΩ50 +/- 0.5
Maximum Frequency GHz0.56
Velocity, percent%98
Capacitance pF/m (pF/ft)68 (20.7)
Inductance, uH/m (uH/ft)µH/m (µH/ft)0.17 (0.052)
Peak Power Rating kW5800
RF Peak Voltage Volts24000
Inner Conductor dc Resistance, Ω/km (Ω/kft)Ω/1000 m (Ω/1000 ft)0.11 (0.034)
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft)Ω/1000 m (Ω/1000 ft)0.031 (0.009)
Return Loss (VSWR) PerformanceStandard
Min. Return Loss (Max. VSWR)dB (VSWR)Typical 20.8dB (1.2 VSWR) or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band.
Phase StabilizedPhase stabilized and phase matched cables and assemblies are available upon request.
Temperature & PowerStandard

Mechanical Specifications

Cable Weight, Nominal kg/m (lb/ft)9.6 (6.48)
Minimum Bending Radius, Single Bendmm (in)1700 (67)
Tensile Strength N (lb)9600 (2158)
Recommended / Maximum Clamp Spacing m (ft)1 / 2 (3.3 / 6.6)

Attenuation @ 20°C (68°F) and Power Rating @ 40°C (104°F)

Frequency, MHzdB per 100mdB per 100ftPower, kW
0.5 0.01 0.00 5800
1 0.02 0.01 5800
1.5 0.02 0.01 5260
2 0.02 0.01 4550
10 0.05 0.01 2010
20 0.07 0.02 1410
30 0.08 0.03 1140
50 0.11 0.03 880
88 0.15 0.05 655
100 0.16 0.05 611
108 0.16 0.05 585
150 0.20 0.06 493
174 0.21 0.07 454
200 0.23 0.07 422
300 0.29 0.09 337
400 0.35 0.11 287
450 0.38 0.12 268
500 0.41 0.12 252
512 0.41 0.13 249
560 0.44 0.13 236
590 0.46 0.14 228

External Document Links