Radio Frequency Systems company website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

ICA12-50JPLR
1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for In-Building Applications, Red Jacket

ClearFill®Line 1/2" low loss air dielectric cable, Plenum-rated, CMP

FEATURES / BENEFITS

  • Supports Multiple RF Signals
  • Complete Shielding
    The solid outer conductor of the ClearFill®Line coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Outstanding Intermodulation Performance
    RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • Wide Range of Applications
    Typical areas of application are feedlines for plenum-space installations within occupied buildings or structures but also suitable for outdoor use due to jacket UV rating.


Technical features

Applications

ApplicationsWireless CommunicationTV & RadioHF DefenseMobile RadioCable SolutionsIn Building

Structure

Cable TypeAir-Dielectric, Corrugated
Size1/2
Inner Conductormm (in)4.8 (0.19)
Dielectricmm (in)11.8 (0.464)
Outer Conductormm (in)13.8 (0.54)
Jacketmm (in)15.93 (0.627)

Testing and Environmental

Flame Retardant, Plenum Rated
Meets/Exceeds Steiner Tunnel Test Method UL 910, NEC 820-53 (a) CMP, NFPA-262.
NEC Article 800 Communication Circuits
ETL Listed to UL444
Canadian CSA C.22.2/FT6
-20 to 60 (-4 to 140) -40 to 85 (-40 to 185) -40 to 85 (-40 to 185)

Electrical Specifications

Impedance, OhmΩ50 +/- 1
Maximum Frequency GHz6
Velocity, percent%91
Capacitance pF/m (pF/ft)76 (23.2)
Inductance, uH/m (uH/ft)µH/m (µH/ft)0.19 (0.058)
Peak Power Rating kW40
RF Peak Voltage Volts2000
Jacket Spark Volt RMS8000
Inner Conductor dc Resistance, Ω/km (Ω/kft)Ω/1000 m (Ω/1000 ft)1.48 (0.45)
Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft)Ω/1000 m (Ω/1000 ft)1.9 (0.58)
Return Loss (VSWR) Performance24 (1.13) @ 698-960 MHz
24 (1.13) @ 1395-1432 MHz
24 (1.13) @ 1700-2155 MHz
20 (1.22) @ 2300-2700 MHz
18 (1.29) @ 3550-4200 MHz
18 (1.29) @ 5150-6000 MHz
Temperature & PowerHigh Power Rating

Mechanical Specifications

Cable Weight, Nominal kg/m (lb/ft)0.37 (0.25)
Minimum Bending Radius, Single Bendmm (in)76 (3)
Minimum Bending Radius, Repeated Bendsmm (in)127 (5)
Bending Moment, Nm (lb-ft)Nm (lb*ft)4.1 (3)
Tensile Strength N (lb)1112 (250)
Recommended / Maximum Clamp Spacing m (ft)0.5 / 0.9 (1.8 / 3)
Crush Strength kg/mm (lb/ln)1.964 (110)

Attenuation and Power Rating

Frequency, MHzdB per 100mdB per 100ftPower, kW
0.5 0.15 0.05 40
1 0.21 0.06 34.30
1.5 0.26 0.08 27.90
2 0.30 0.09 24.20
10 0.67 0.20 10.70
20 0.95 0.29 7.55
30 1.17 0.36 6.15
50 1.52 0.47 4.74
88 2.04 0.62 3.53
100 2.18 0.67 3.30
108 2.27 0.69 3.17
150 2.70 0.82 2.67
174 2.92 0.89 2.47
200 3.14 0.96 2.30
300 3.89 1.19 1.85
400 4.54 1.39 1.59
450 4.84 1.48 1.49
500 5.13 1.56 1.41
512 5.19 1.58 1.39
600 5.66 1.73 1.28
700 6.16 1.88 1.17
750 6.40 1.95 1.13
800 6.64 2.02 1.09
824 6.75 2.06 1.07
894 7.06 2.15 1.02
900 7.08 2.16 1.02
925 7.19 2.19 1.01
960 7.34 2.24 0.99
1000 7.51 2.29 0.96
1250 8.52 2.60 0.85
1400 9.08 2.77 0.80
1500 9.45 2.88 0.77
1700 10.20 3.09 0.71
1800 10.50 3.20 0.69
2000 11.20 3.40 0.65
2100 11.50 3.50 0.63
2200 11.80 3.59 0.62
2300 12.10 3.69 0.60
2400 12.40 3.78 0.59
2500 12.70 3.87 0.58
2600 13 3.96 0.56
2700 13.30 4.05 0.55
3000 14.10 4.31 0.52
3500 15.50 4.73 0.47
3600 15.80 4.81 0.47
4000 16.80 5.13 0.44
4500 18.10 5.51 0.41
5000 19.30 5.88 0.38
5500 20.40 6.23 0.36
6000 21.60 6.58 0.34

Notes