RLKAX12-50JFNA
1/2" RADIAFLEX® RLKAX Cable, A-series
Rev : A | Rev date : 14 Dec 2022
- RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.
- Slots in the copper outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties.
FEATURES / BENEFITS
- Ultra-wideband from 30 MHz to 7200 MHz
- Support of 4G and 5G wireless bands and WLAN standards
- Suitable for a wide range of applications in tunnels and buildings
- Low coupling loss variations for balanced system design througout the overall supported spectrum
RLKAX12-50JFNA
General Specifications |
---|
Size | | 1/2 |
|
Electrical Specifications |
---|
Max. Operating Frequency | MHz | 7200 | Cable Type | | RLKAX | Impedance | Ohm | 50 +/- 2 | Velocity, percent | % | 88 | Capacitance | pF/m (pF/ft) | 75 (22.86) | DC-resistance inner conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 1.97 (0.6) | DC-resistance outer conductor, ohm/km (ohm/1000ft) | Ω/km (Ω/1000ft) | 4.84 (1.48) | Stop bands | MHz | 1900-2190 | Frequency Selection | MHz | 2400, 2600, 3500, 3800, 4200, 4900, 5800, 7000 |
|
Mechanical Specifications |
---|
Jacket | | JFN | Jacket Description | | Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin | Slot Design | | Groups of vertical slots at short intervals | Inner Conductor Material | | Copper Clad Aluminum Wire | Outer Conductor Material | | Overlapping Copper Foil | Diameter Inner Conductor | mm (in) | 4.37 (0.17) | Diameter Outer Conductor | mm (in) | 11.4 (0.45) | Diameter over Jacket Nominal | mm (in) | 14.7 (0.58) | Minimum Bending Radius, Single Bend | mm (in) | 200 (7.9) | Cable Weight | kg/m (lb/ft) | 0.23 (0.16) | Tensile Force | N (lb) | 1300 (292) | Indication of Slot Alignment | | Bulge atop slots | Recommended / Maximum Clamp Spacing | m (ft) | 0.5 (1.6) | Minimum Distance to Wall | mm (in) | 80 (3.15) |
|
Testing and Environmental |
---|
Jacket Testing Methods | | Test methods for fire behaviour of cable : IEC 60754-1/-2 smoke emission: halogen free, non corrosive IEC 61034 low smoke IEC 60332-1 flame retardant IEC 60332-3-24 fire retardant UL1666, ASTM E 662, NES711 and NES713 EN50575:2014 + A1:2016 (Hannover production) class Cca s1a d1 a1 |
|
Temperature Specifications |
---|
Storage Temperature | °C(°F) | -70 to 85 (-94 to 185 ) | Installation Temperature | °C(°F) | -25 to 60 (-13 to 140 ) | Operation Temperature | °C(°F) | -40 to 85 (-40 to 185 ) |
|
Attenuation and Power Rating | Frequency, MHz | Longitudinal Loss, dB/100 m (dB/100 ft) | Coupling Loss 50%, dB | Coupling Loss 95%, dB |
75 |
2.09 (0.64) |
62 (65) |
72 (75) |
150 |
2.96 (0.90) |
72 (75) |
81 (85) |
450 |
5.25 (1.60) |
75 (78) |
86 (89) |
700 |
6.60 (2.01) |
74 (78) |
85 (88) |
900 |
7.57 (2.31) |
74 (77) |
84 (87) |
1500 |
10.0 (3.05) |
79 (82) |
90 (92) |
1700 |
10.8 (3.29) |
73 (76) |
84 (86) |
1800 |
11.1 (3.38) |
75 (77) |
86 (88) |
2200 |
12.8 (3.90) |
64 (68) |
73 (77) |
2400 |
13.4 (4.08) |
68 (70) |
75 (77) |
2600 |
14.1 (4.30) |
66 (69) |
71 (75) |
2700 |
14.5 (4.42) |
68 (70) |
74 (77) |
3200 |
15.8 (4.82) |
68 (72) |
74 (79) |
3400 |
16.4 (5.00) |
67 (71) |
72 (76) |
3600 |
17.0 (5.18) |
68 (72) |
72 (77) |
3800 |
17.7 (5.39) |
66 (70) |
70 (75) |
4000 |
18.5 (5.64) |
69 (73) |
74 (78) |
4200 |
19.1 (5.82) |
64 (68) |
68 (73) |
4800 |
21.1 (6.43) |
66 (70) |
71 (76) |
5000 |
21.8 (6.64) |
65 (69) |
70 (75) |
5200 |
22.5 (6.86) |
65 (69) |
70 (75) |
5400 |
23.3 (7.10) |
65 (69) |
69 (73) |
5600 |
24.2 (7.38) |
66 (69) |
70 (75) |
5800 |
25.1 (7.65) |
66 (70) |
72 (76) |
6000 |
26.0 (7.92) |
64 (68) |
69 (73) |
6200 |
26.8 (8.17) |
65 (68) |
69 (74) |
6400 |
28.0 (8.53) |
64 (68) |
70 (74) |
6600 |
29.1 (8.87) |
63 (67) |
68 (72) |
6800 |
30.5 (9.30) |
63 (67) |
69 (73) |
7000 |
32.1 (9.78) |
63 (67) |
69 (73) |
7200 |
33.9 (10.3) |
63 (66) |
68 (72) |
|
Notes
- RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
- This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a smooth copper outer conductor which offers a superior electrical performance together with good bending properties
- Coupling loss values are measured with dipole (75 - 4200MHz) and biconical antenna (4400-7200MHz). Values are normalized to half-wave dipole. The coupling loss values given in brackets are average values of all three spatial orientations (radial, parallel and orthogonal)
- Coupling loss values are given with tolerances of +5dB and longitudinal loss values with a tolerance of +5%
- Measured values below nominal are better. Note: measured values below nomila are better. They are not limited by any tolerance range
- Coupling as well as longitudinal loss of RFS RADIAFLEX® cables are measured by free-space method according to IEC 61196-4
- In case of a conflict of operational and stop band, please contact RFS for further assistance
- As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free-space method